CHXYM - CHROMABASE CLEAR ACTIVATORS, REDUCERS, 7899S

Product Identification

Product ID:CHROMABASE CLEAR ACTIVATORS, REDUCERS, 7899S
MSDS Date:01/01/1997
FSC:8010
NIIN:00N090099
Status Code:A
MSDS Number: CHXYM

Responsible Party
E I DUPONT DE NEMOURS & CO INC
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Preparer: TR LOUER

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

0.1 @ 20C

CAS: 108419-34-7

OSHA PEL N/K

ACGIH TLV: N/K


ALIPHATIC POLYMERIC ISOCYANATE

CAS: 3779-63-3

OSHA PEL N/K

ACGIH TLV: N/K


6.7 @ 20C

CAS: 88230-35-7

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


1,6-HEXAMETHYLENE DIISOCYANATE

CAS: 822-02-0

RTECS: MO1740000

OSHA PEL N/K

ACGIH TLV: N/K


2.5

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


TO SIT 10 MINS, MIN. TYPICAL DECONTAM SOLNS

RTECS: 9999999ZZ


0-10% AMMONIA; 2-5% DETERGENT; BALANCE WATER.

RTECS: 9999999ZZ


AFTER 48 HOURS, MATERIAL MAY BE SEALED AND DISPOSED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST: GI DISTRESS. INHAL: MAY
CAUSE NOSE & THROAT IRRIT. RPTD & PRLNG OVEREXP TO SOLVS MAY LEAD
TO PERM BRAIN & NERV SYS DMG. EYE WATERING, HDCH, NAUS, DIZZ & LOSS
OF COORD ARE SIGNS THAT SOL V LEVELS ARE TOO HIGH. EXPOS TO
ISOCYANATES MAY CAUSE RESP SENSIT. THIS EFT MAY BE PERM. THIS EFT
MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: BE DELAYED FOR SEVERAL HRS AFTER
EXPOS. RPTD OVEREXP TO ISOCYANATES MAY CAUSE DECR IN LUNG FUNC
WHICH MAY BE PERM. EYES: MAY CAUSE IRRIT/BURNING. SKIN: RPTD/PRLNG
LIQ CONT MAY CAUSE IRRIT W/ DISCOMFORT & DERM. RPTD EXPOS MAY
CAUSEALLERGIC SKIN RASH, ITCH, SWELL. MAY CAUSE EYE IRRIT
W/DISCOMFORT, (SUP DAT)
Medical Cond Aggravated by Exposure:PERS W/HISTORY OF LUNG/BRTHG
PROBLEMS/PRIOR RXN TO ISOCYANATE SHOULD NOT USE/BE EXPOSED. PERS
W/PREEXISTING LUNG DISEASE, ASTHMA/BRTHG DFCLTYS MAY HAVE INCRD
SUSCEPTIBILITY TO TOX OF EXCESS EXPOS.

First Aid

First Aid:INGESTION: IN THE UNLIKELY EVENT OF INGESTION, CALL MD
IMMEDIATELY AND HAVE NAMES OF INGREDIENTS AVAILABLE. DO NOT INDUCE
VOMITING. INHALATION: REMOVE TO FRESH AIR. IF BREATHING DIFFICULTY
PERSISTS OR OCCURS LATER, CONSULT MD. EYES: IMMEDIATELY FLUSH WITH
PLENTY OF WATER FOR AT LEAST 15 MINUTES. CALL MD. SKIN: WASH WITH
SOAP AND WATER. IF IRRITATION OCCURS, CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:100F,38C
Lower Limits:0.8%
Upper Limits:13.1%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FLASH POINT, EMITS
FLAMMABLE VAPS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLO. FINE
MISTS/SPRAYS MAY BE FLAMMABLE AT TEMPS BELOW FLASH POINT.

Accidental Release

Spill Release Procedures:DO NOT BREATHE VAPS. DO NOT GET IN EYES/ON
SKIN. WEAR POS PRESS SUPPLIED AIR VAP/PARTICULATE RESP (NIOSH
TC-19C), EYE PROT, GLOVES & PROT MATL. REMOVE SOURCES OF IGNIT.
ABSORB W/INERT MATL. VENT AREA. POUR LIQ DECONTAM SOLN OVER SPILL
& ALLOW (ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS AND FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND
CONTAINERS WHEN POURING.
Other Precautions:DO NOT STORE ABOVE 120F. DO NOT SAND, FLAME CUT,
BRAZE OR WELD DRY COATING WITHOUT A NIOSH APPROVED RESPIRATOR OR
APPROPRIATE VENTILATION. DO NOT BREATHE VAPORS OR SPRAY MISTS.

Exposure Controls

Respiratory Protection:WEAR POS PRESS SUPP AIR RESP (NIOSH TC-19C)
WHILE MIXING ACTIVATOR W/ANY PAINT/CLEAR ENAMEL, DURING APPLICATN &
UNTIL ALL VAPS & SPRAY MISTS ARE EXHAUSTED. DO NOT LET ANYONE W/OUT
PROT IN PAINTING ARE A. FOLLOW RESP MFR'S DIRECTIONS FOR USE.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . COVERALLS RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
% VOLAT: 34.3-97.2. EFTS OF OVEREXP: TEARING/BLURRED VISION. RPTD
OVEREXP TO ISOCYANATES MAY CAUSE LUNG INJURY, INCL DECR IN LUNG
FUNC, WHICH MAY BE PERM. OVEREXP MAY CAUSE ASTHMA-LIKE RXNS
W/SHORTNES S OF BREATH, WHEEZING, COUGH, WHICH MAYBE PERM/PERM LUNG
SENSIT. THIS EFT MAY BE DELAYED FOR SEVERAL HRS AFTER EXPOS.

Chemical Properties

Boiling Pt:B.P. Text:>169F,>76C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.06
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.